How to troubleshoot inaccurate AccuFlow measurements on my Raven AccuFlow Vortex control console?
- CChristine StokesNov 24, 2025
First, verify that the target application speed is below the maximum speed allowed for the implement width and the target rate using the System Capacity Chart. If exceeded, reduce the application speed. Then, verify that the AccuFlow system is plumbed correctly using the stem diagrams. Ensure that the difference between the static and operating pressures does not exceed 5 PSI. If it does, clean the strainer next to the Vortex cooler, check hoses for deterioration, and replace if necessary. Remove excess hose length between the nurse tank and break-away coupler and between the break-away coupler and the AccuFlow system. Verify that the break-away coupler is 1-1/2”, not 1”. Finally, verify flow through the Vortex cooler chamber by removing the vapor hoses from the steel vapor tubes at applic...