CHAPTER 7
78 AccuFlow™ Vortex and AccuFlow™ HP+ Installation and Operation Manual
TESTING THE FLOW METER CABLE
1. Enter a meter cal of 1 in liquid or direct injection modes, or density of 1 and spreader constant of 0 in granular
mode.
2. Navigate to the volume/area settings screen and note the total volume for each product node connected to
the CANbus.
3. Turn the boom and master switch ‘on.’
4. With a small jumper wire (or paper clip), short between the 2 o’clock and 6 o’clock sockets with a ‘short-no-
short’ motion. Each time contact is made, the total volume number should increase by increments of 1 or more.
5. If the total volume value does not increase, remove the section of cable and repeat the test at the connector
that is the next closest to the node. Replace the defective cable as required.
6. Verify the pin connection and voltage from the previous chart.
7. If all of the cables test good, replace the rate sensor.
NOTE: After testing is complete, re-enter the correct cal values before starting an application.
CONTROL VALVE WIRING
MASTER ON/OFF AND SECTION VALVE PIN OUT
FIGURE 4. Master On/Off and Section Valves Plug End Pins
FIGURE 5. Control Valve Plug End Pins
Ground
Signal
Power (12v)
Status (Not Activated in
AccuFlow and AccuFlow
HP Cabling)
Ground
Decrease
Power (12v)
Increase