How to troubleshoot Raven Farm Equipment when pressure and temperature gauge readings indicate NH is not in a liquid state?
- BBecky KeySep 8, 2025
Check that the vapor tubes have been affixed to the applicator knives correctly and that the openings for NH are not plugged or filled with debris. If additives such as N-Serve or ACA have been or are being used with the AccuFlow system, disassemble and clean Vortex cooler chamber. Determine if the operating pressure drop is within tolerances.