QuickStat
®
Thermostat
Installation & Operation Manual
General Information
Use of this Manual
This manual covers the installation and operation of the Raychem
®
QuickStat
®
thermostat and must be used with the following document:
• QuickNet
®
System Installation Manual (H57704)
Important: For the Tyco Thermal Controls warranty and agency approv-
als to apply, the instructions included in this manual and product pack-
ages must be followed.
Features
QuickStat is an electronic thermostat that must be used with the
Raychem QuickNet floor heating mats.
QuickStat provides the following features:
• IncludesanintegratedClassA,Ground-faultCircuitInterrupter(GFCI)
at120V.IftheQuickStatispoweredat208Vor240V,aseparate
GFCImustbeused.
• Operatesat120V,208V,240V50/60Hz.
• Switchesonyourheatingsystematpredeterminedtimesondifferent
days of the week.
• Offers4periods(calledevents)eachdaythatyoucansetatdifferent
temperatures.
• Comeswithapreprogrammedschedulethatissuitableformost
installations.However,youcancustomizethisprogramanytimeyou
wish.
• Allowsyoutoresetthethermostattofactorysettings.
• Changesthestarttimeofaheatingperiodautomaticallysothatthe
desired temperature is reached at the time that you set.
• Controlsthetemperatureofthefloorthroughatemperaturesensor
that is placed in the floor construction.
Specifications
Approvals
Technical Data
SupplyVoltage 120V,208V,240V±15%,50/60Hz
Maximum switching current 15 A
Wiring 12AWGto22AWG
GFCI ClassA,5mAtriplevel(at120Vonly)
Temperature control range 40 to 104°F (5 to 40°C)
Ambient temperature range
Thermostat 32 to 104°F (0 to 40°C)
GFCI –31to149°F(–35to65°C)
Kit contents
A 1 QuickStat thermostat
B 2 Mounting screws
C 1 Floor temperature sensor 10 ft (3m)