6.2Troubleshooting
IssueAction
Nopower
Check:
Allpowerconnections
Checkrelevantfuses
Thatpowersupplyisatthecorrectvoltage(12Vor24V)
AISconguration
dataisnotsaved
Switchoffallassociatedmulti-functiondisplays(MFDs),
thenre-congure
Nodata
Checkthat:
Connectionsaresecurethroughoutthesystem
TheVHFaerialleadissecurelyconnectedandthatyou
cansendandreceiveVHFradioinformation
Novesseldata
AttherelevantRaymarinemultifunctiondisplay:
Placethecursoroverthetargetedvesselandensure
theAISDATAsoftkeyisnotsettoOFF
EnsuretheAISlayerissettoON
EnsuredisplayedtargettypesaresettoALL
NoAISdataChecktheNMEAoutputfromthemulti-functiondisplaysto
theAIS500input,andensure:
Thewiresarecorrectlyconnected
Thebaudrateis38400baud
Statusindicator
remainsamber
Waitatleast30minutestocheckthata’Quiettime’has
notbeenrequestedbythelocalauthority
Checkthatthe:
GPSantennaisproperlyconnected
GPSantennahasaclearviewofthesky,withoutany
obstructions
MMSInumberhasbeenproperlycongured(usethe
proAISapplication)
Statusindicatoris
red
Checkthat:
TheVHFantennaisproperlyconnectedandinparticular
itisnotshortcircuitingtothevesselstructure
Thatpowersupplyisatthecorrectvoltage(12Vor24V)
TheMMSInumberhasbeenproperlycongured(use
theproAISapplication)