6.2Troubleshooting
IssueAction
Nopower
Check:
•Allpowerconnections
•Checkrelevantfuses
•Thatpowersupplyisatthecorrectvoltage(12Vor24V)
AISconguration
dataisnotsaved
Switchoffallassociatedmulti-functiondisplays(MFDs),
thenre-congure
Nodata
Checkthat:
•Connectionsaresecurethroughoutthesystem
•TheVHFaerialleadissecurelyconnectedandthatyou
cansendandreceiveVHFradioinformation
Novesseldata
AttherelevantRaymarinemultifunctiondisplay:
•Placethecursoroverthetargetedvesselandensure
theAISDATAsoftkeyisnotsettoOFF
•EnsuretheAISlayerissettoON
•EnsuredisplayedtargettypesaresettoALL
NoAISdataChecktheNMEAoutputfromthemulti-functiondisplaysto
theAIS500input,andensure:
•Thewiresarecorrectlyconnected
•Thebaudrateis38400baud
Statusindicator
remainsamber
Waitatleast30minutestocheckthata’Quiettime’has
notbeenrequestedbythelocalauthority
Checkthatthe:
•GPSantennaisproperlyconnected
•GPSantennahasaclearviewofthesky,withoutany
obstructions
•MMSInumberhasbeenproperlycongured(usethe
proAISapplication)
Statusindicatoris
red
Checkthat:
•TheVHFantennaisproperlyconnectedandinparticular
itisnotshortcircuitingtothevesselstructure
•Thatpowersupplyisatthecorrectvoltage(12Vor24V)
•TheMMSInumberhasbeenproperlycongured(use
theproAISapplication)
Diagnostics
41