Highalarmloadsandthirdpartyalarms
Youcanusethealarmoutputtoswitcharelay.Thismaybeuseful
forconnectinghighloadssuchasthirdpartyalarmsoundersor
inductiveloadstotheC-Seriesmultifunctiondisplay.Ifyouarein
anydoubtastohowtomakesuchconnectionspleaseconsultan
authorizedinstaller.
TheC-Seriesmultifunctiondisplayhasapositiveswitchedalarm
output.Thefollowingcircuitshowsthearrangementforconnection
ofarelayswitch.
Alarmoutputconguredtoswitcharelay
High current load
Battery
+
Battery
--
0v return
Relay
Suppression
diode
Alarm out
(+ve)
D11591-1
Note:Whenconnectingtheoutputtoarelayorotherinductive
deviceyoushouldtaspikesuppressiondiodee.g.1N4001.
3.8GPSconnection
DependinguponyourGPStypeitmaybeeitherconnectedvia
SeaTalkorNMEA0183.
Seealso
ForSeaTalkconnectionreferto:3.6SeaT alkconnection.
ForNMEA0183connectionreferto:3.5NMEA0183connection.