EasyManua.ls Logo

Raymarine E70498 - Page 52

Raymarine E70498
100 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
1
P
ositive(+)bar
2
Negative(-)bar
3Circuitbreak
er
4Fuse
Inallcases,observetherecommendedbreak
er/fuseratingsprovidedintheproduct’s
documentation.
Important:
Beawarethatthesuitablefuseratingforthethermalbreak
erorfuseisdependentonthenumber
ofdevicesyouareconnecting.
P owercableextension
Ifyouneedtoextendthelengthofthepowercablesuppliedwithyourproduct,ensureyouobserve
thefollowingadvice:
Thepowercableforeachunitinyoursystemshouldberunasaseparate,singlelengthof2-wire
cablefromtheunittothevessel'sbatteryordistributionpanel.
Forpowercableextensions,itisrecommendedthataminimumwiregaugeof16AWG(1.31mm
2
).
Forcablerunslongerthan15meters,youmayneedtoconsiderathickerwiregauge(e.g.14AWG
(2.08mm
2
),or12AWG(3.31mm
2
)).
Animportantrequirementforalllengthsofpowercable(includinganyextension)istoensure
thatthereisacontinuousminimumvoltageof10.8Vattheproduct’spowerconnector,witha
fullyflatbatteryat11V.
Important:Beawarethatsomeproductsinyoursystem(suchassonarmodules)cancreatevoltage
peak satcertaintimes,whichmayimpactthevoltageavailabletootherproductsduringthepeaks.
Grounding
Ensurethatyouobservetheseparategroundingadviceprovidedintheproduct’ sdocumentation.
Moreinformation
Itisrecommendedthatbestpracticeisobservedinallvesselelectricalinstallations,asdetailed
inthefollowingstandards:
BMEACodeofPracticeforElectricalandElectronicInstallationsinBoats
NMEA0400InstallationStandard
ABYCE-11AC&DCElectricalSystemsonBoats
ABYCA-31BatterychargersandInverters
ABYCTE-4LightningProtection
Warning:Groundingnotrequired
ThisproductisfullyinsulatedanddoesNOTrequireseparategrounding.