1.V essel’slongitudinalaxis.
7.4LocationrequirementsACU
Theinstallationlocationmusttakeintoaccountthefollowingrequirements:
ACU-200,ACU-300,ACU-400installbelowdecksinadryarea.
ACU-100,ACU-150installaboveorbelowdecks.
Theunitshouldbemountedonaverticalsurface.
Theunitshouldbelocatedasclosetothebatteryaspractical.
Choosealocationwheretheunitwillbesafefromphysicaldamageandexcessivevibration.
Choosealocationwheretheunitwillnotbesubjectedtoaloadorforce.
Mountawayfromanysourceofheatorpotentialflammablehazards,suchasfuelvapor.
TheunitshouldbemountedinalocationwherethediagnosticsLEDisviewable.
L ocationrequirements