1.A CU(ActuatorControlUnit)
2.Powersupply/distributionpanel
3.Driveunit
Poweranddrivecableselection
DriveSupplyvoltageMax.length(A +B)Cablesize
0–7m(0–23ft)2.5mm
2
(14AWG)
T ype0.5hydraulic
pump
12V
7–10m(23–32.8ft)4mm
2
(12AWG)
0–7m(0–23ft)2.5mm
2
(14AWG)
T ype1drive
CRpump(ACU–300
only)
12V
7–10m(23–32.8ft)4mm
2
(12AWG)
0–5m(0–16.4ft)6mm
2
(10AWG)
12V
5–7m(16.4–23ft)10mm
2
(8AWG)
0–3m(0–9.8ft)4mm
2
(12AWG)
3–5m(9.8–16.4ft)6mm
2
(10AWG)
T ype2drive
24V
5–10m(16.4–32.8ft)10mm
2
(8AWG)
12V
0–5m(0–16.4ft)10mm
2
(8AWG)
0–5m(0–16.4ft)6mm
2
(10AWG)
T ype3drive
24V
5–7m(16.4–23ft)10mm
2
(8AWG)
0–7m(0–23ft)2.5mm
2
(14AWG)
WheeldriveSail12V
7–10m(23–32.8ft)4mm
2
(12A WG)
0–7m(0–23ft)2.5mm
2
(14AWG)
WheeldriveP ower
(SportDrive)
12V
7–10m(23–32.8ft)4mm
2
(12AWG)
0–7m(0–23ft)2.5mm
2
(14AWG)
Tillerdrive
12V
7–10m(23–32.8ft)4mm
2
(12A
WG)