Ral~heon
Aircraft
Company
BARON
55
AND
58
SHOP
MANUAL
2.
With
both
engines
running
at
minimum
cruise
rpm
and
both
alternators
on,
turn
on
all
possible
electrical
loads.
Check
to
see
if
the
alternators
share
the
load
to
within
10
percent
of
the
rated
output
of
one
of
the
alternators.
If
they
do
not
share
the
electrical
load
as
described,
refer
to
ALTERNATOR
PARALLELINGprocedure.
I
m.
Shut
down
the
left
and
right
engines
according
to
the
ENGINE
SHUT
DOWN
procedures
in
the
applicable
Pilot’s
Operating
Handbook.
n.
Remove
the
precision
voltmeter
from
the
airplane.
AL
TERNA
TOR
PARALLELING
On
the
airplanes,
which
use
one
regulator
to
regulate
the
output
of
both
of
the
alternators,
there
are
no
provisions
for
paralleling
the
alternators.
Unbalanced
outputs
between
the
alternators
can
be
caused
by:
(1)
voltage
drops
in
the
charging
system
wiring;
(2)
voltage
drops
in
the
ground
circuit
connections;
(3)
manufacturing
tolerances
in
the
alternators;
(4)
variations
in
the
overall
resistance
characteristics
between
the
two
charging
circuits;
(5)
operating
temperature
of
the
alternators
and
the
voltage
regulator,
and
(6)
the
engine
rpm.
If
either
alternator
is
turned
off
and
the
remaining
alternator
picks
up
the
load,
the
alternators
are
functioning
I
properly.
Alternator
charging
systems,
unlike
the
generator
systems,
do
not
require
a
balanced
output
to
prevent
component
damage.
E21
SECTION
13
DePcag3~Page
19