EasyManua.ls Logo

Raytheon Beech Baron E55 - Page 675

Raytheon Beech Baron E55
903 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Raytheon
nircraft
Company
BARON
55
AND
58
SHOP
MANUAL
Chart
28
TROUBLESHOOTING
NICKEL-CADMIUM
BATTERIES
(Continued)
INDICATION
PROBABLE
CAUSE
REMARKS
3.
(Cont.)
c.
Vent
caps
loose
or
broken,
c.
Clean
cell,
replace
ortighten
vent
cap.
d.
Cracked
cell
case.
d.
Replace
cell,
clean
battery.
4.
Cell
cases
distorted,
a.
Excessive
charge
rate.
a.
Clean
the
battery,
recondition,
adjust
the
electrolyte
level
and
capacity
test.
Adjust
voltage
regulator
of
airplane.
b.
Cell
with
internal
short.
b.
Replace
defective
cell,
recondition
and
capacity
test.
c.
Plugged
vent
caps,
minor
c.
Disassemble,
replace
defective
explosion.
parts,
clean
the
battery,
recondition
and
capacity
test.
5.
Unequal
voltages
among
cells,
a.
Cells
unbalanced.
a.
Equalize
cell
voltages
(perform
a
full
capacity
discharge
cycle)
capacity
test.
6.
Foreign
matter
within
cells.
a.
Impure
or
acid-contaminated
a.
Such
cells
will
not
normally
water,
respond
to
charging.
They
will
show
up
as
unbalanced
cells
and
must
be
replaced.
7.
Frequent
addition
of
water.
a.
Unbalanced
cells.
a.
Equalize
cell
voltages.
b.
Leaky
or
defective
cells,
damage
b.
Replace
defective
parts
and
to
O-ring
or
vent
cap.
inspect
for
electrolyte
leakage.
Clean,
recondition
and
level
electrolyte.
8.
Burn
markson
connectors.
a.
Loose
connectors.
9.
Overheatingof
intercell
a.
Loose
or
dirty
intercell
connectors,
a.
Disassemble,
clean,
reassemble
connectors.
and
properly
torque
intercell
connectors,
capacity
test.
10.
Foam
or
bubbling
during
a.
Oil
or
grease
contamination
in
the
a.
Replace
defective
cells.
charging,
electrolyte.
b.
Low
concentration
of
electrolyte.
b.
Recondition,
replace
cells
that
continue
to
foam.
11.
Below
normal
output.
a.
Battery
switch
left
ON.
Recharge
and
capacity-test.
b.
Voltage
regulator
set
to
low.
b.
Recharge
and
capacity-test.Reset
voltage
regulator.
c.
Internal
connection
links
loose.
c.
Torque,
recharge
and
capacity-
test.
d.
External
connector
burned
or
d.
Clean
or
replace,
recharge
and
pitted.
capacity-test.
Dec
31/03Page
78
SECTION
13
EZ1

Table of Contents

Related product manuals