Chart
31
TROUBLESHOOTING
FULL
TRANSISTOR
REGULATOR
9000591
TYPE
24
VOLT
(Continued)
INDICATION
PROBABLE
CAUSE
REMARKS
6.
High
systemvoltage.
a.
Driver
transistor
open.
a.
Negative
or
positive
grounded
system:
1.
Defective
transistor.
7.
Nocharge.
a.
Zener
diode
shorted.
a.
Either
system:
1.
Reverse
battery
polarity.
2.
High
system
voltage.
3.
Defective
zener.
8.
High
systemvoltage.
a.
Zener
diode
open.
a.
Either
system:
1.
Defective
zener.
9.
Shorted
outputtransistorand
a.
Field
discharge
diode
open.
a.
Either
system:
high
system
voltage.
1.
Reverse
battery
polarity.
2.
Defective
diode.
10.
No
charge.
a.
Back
bias
diode
open.
a.
Negative
grounded
systems:
1.
Severe
ground
at
F
terminal
of
generator.
2.
Severe
ground
in
wiring
between
F
terminals
of
generator
and
regulator.
3.
Generator
field
completely
shorted.
4.
Defective
diode.
b.
Positive
grounded
systems:
1.
Sever
short
between
F
and
negative
leads
between
generator
and
regulator.
2.
Generator
field
completely
shorted.
3.
Defective
diode.
11.
Poor
switching
which
would
a.
Back
bias
diode
shorted.
a.
Negative
grounded
systems:
cause
shorted
output
transistor.
1.
F
terminal
of
generator
has
been
grounded.
2.
Poor
ground
in
system
or
poor
connection
at
generator
or
regulator.
3.
Regulator
too
hot.
4.
Ground
in
wiring
between
F
terminals
of
generator
and
regulator.
5.
Defective
transistor.
6.
Shorted
field
in
generator.
7.
Defective
diode.