EasyManua.ls Logo

RC MI2S-600D - Power on the Solar System; Set up Monitoring System

RC MI2S-600D
23 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
MI2S-600D/700D/800D 17
If the DC input voltage of the inverter is higher than the minimum startup voltage, the status
indicator on the inverter blinks green within two minutes.This time varies by region of
sale
Make sure that the AC Trunk Connectors are kept away from any drainage channels.
If you need to remove the micro inverter AC cable from AC Trunk Connector, insert the AC
Trunk Port Disconnect Tool into the AC Sub Connector to complete the removal.
Only qualified personnel can connect the inverter to the power grid.
Before connecting the system to the grid, ensure that all AC and DC connections are
correct and not damaged. Make sure all junction boxes are connected.
If there is a poor Wi- Fi signal strengthplease contact the network operator and ask about
the network problems.If the WiFi signal is still weak,try to add a Wi-Fi booster to your
network.
WARNING
WARNING
WARNING
CA UT IO N
CA UT IO N
CA UT IO N
6.7 Set up Monitoring System
6.6 Power on the solar system
A) Check the installation of each branch of the system to ensure that the connection is correct and reliable.
B) Turn on the main connection circuit breaker of the AC bus box.
C) Turn on the AC circuit breakers for each branch of the AC bus box.
D)
If the DC input voltage of the inverter is within the working voltage range, the system will start to
generate power several minutes after the AC is switched on.
A) Collect the serial number of each micro inverter in the current project.
B) Fill the serial number label of every inveter to the respective location on the installation map
(please refer to the appendix).
C) Scan the Quick Response code to download and install the RCMI application.After finishing
installation, please update the RCMI applation to the latest version.
D) Connect the micro inverter to the the network by RCMI application.Please refer to the RCMI
Operating Guide to set up monitoring system about this process.
Apple Store
Android