EasyManua.ls Logo

RCF ES 3080 - Power Supply Voltage Change; Voltage Selection Procedure

RCF ES 3080
32 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
15
ENGLISH
POWER SUPPLY VOLTAGE CHANGE
IMPORTANT: This manual section concerns qualied personnel only.
The following instructions are to be ignored by users.
Make sure the device is not connected to the mains (unplug the power cord).
Remove the lid.
Find the 230 / 115 V voltage change connector (in the picture, it is highlighted by a square).
According to the PCB indication, if the mains voltage is 230 V, set the connector to the 230 V
position, if the mains voltage is 115 V, set the connector to the 115 V position.
Ret the device lid.
Before connecting the device to the mains, make sure that the fuse (inside the IEC power
supply connector of the rear panel) is the correct current rating for the mains voltages (read
the fuse indication below the connector).