WorkHorse Read This First
page 8 RD Instruments
Mounting PlateA bronze plate that helps mount the transducer
head to a vessel. See the Installation Guide outline installation
drawings for dimensions.
6 WorkHorse Care
This section contains a list of items you should be aware of every time you
handle, use, or deploy your WorkHorse. Please refer to this list often.
6.1 General Handling Guidelines
Never set the transducer on a hard or rough surface. The ure-
thane faces may be damaged.
Always remove the retaining strap on the end-cap underwater-
connect cable and dummy plug when disconnecting them. Fail-
ure to do so will break the retainer strap.
Do not apply any upward force on the end-cap connector as the
I/O cable is being disconnected. Stressing the end-cap connec-
tor may cause the ADCP to flood. Read the Maintenance guide
for details on disconnecting the I/O cable.
Do not expose the transducer faces to prolonged sunlight. The
urethane faces may develop cracks. Cover the transducer faces
on the Workhorse if it will be exposed to sunlight.
Do not expose the I/O connector to prolonged sunlight. The
plastic may become brittle. Cover the connector on the Work-
horse if it will be exposed to sunlight.
Do not store the ADCP in temperatures over 75 degrees C. The
urethane faces may be damaged. Check the temperature indi-
cator inside the shipping case. It changes color if the temperature
limit is exceeded.
Store batteries in a cool dry location (0 to 21 degrees C).
Do not store batteries inside the ADCP for extended periods.
The batteries may leak.
Vent the system before opening by loosing the end-cap. If the
ADCP flooded with batteries installed, there may be gas un-
der pressure inside the housing.
Do not scratch or damage the O-ring surfaces or grooves. If
scratches or damage exists, they may provide a leakage path
and cause the ADCP to flood. Do not risk a deployment with
damaged O-ring surfaces.
Do not lift or support a WorkHorse by the external I/O cable.
The connector or cable will break.

Other manuals for RD Instruments WorkHorse

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the RD Instruments WorkHorse and is the answer not in the manual?

RD Instruments WorkHorse Specifications

General IconGeneral
BrandRD Instruments
ModelWorkHorse
CategoryMeasuring Instruments
LanguageEnglish

Related product manuals