Parameter explanations V2.1_V2.6
2
IRA_B8_EN_2V2_REC_102-020401137 12/ 56
Two motors This parameter indicates whether one or two motors are con-
nected to the STM. Normally, the second motor is automatical-
ly identified.
Two motors can only be configures if the STM has been
planned accordingly (DUO).
In case of RED doors 2 motors are compulsory.
Disabled X One motor is connected.
Enabled Two motors are connected.
Emergency operating BAT This parameter determ
ines the last action of the door controller
in battery operation. A second parameter
Power failure
(see
below) determines if this emergency operation should be exe-
cuted immediately after a power failure or only in case of low
battery capacity.
At the end of the emergency operation (door open/closed)
the battery is completely disconnected, at the latest after
60 seconds. This state will only be exited upon return of
mains voltage.
The last door movement happens at reduced speed. In
doing so, safety sensors are not taken into account, only
the collision identification is enabled.
An emergency closing (NSK) or emergency opening (SÖK)
takes precedence over the configured emergency opera-
tion. Afterwards, the battery is also disconnected.
If the battery capacity allows, the battery can be used for a
single door opening with the SSK.
With RED doors only emergency operations in opening
direction are configurable.
Close, do not lock Regardless of the operating mode the door is closed but not
locked.
Unlock and open Regardless of the operating mode the door is completely
opened. If necessary, it is unlocked beforehand.
Close and lock Regardless of the operating mode the door is closed and af-
terwards locked.
Open if not locked X In the
Locked
operating mode the door remains locked or it is
locked after the next closing at the latest. In all the other oper-
ating modes the door is completely opened.

Related product manuals