Parameter explanations V2.1_V2.6
2
IRA_B8_EN_2V2_REC_102-020401137 9/ 56
Reset with button Enables an early closing of the door by sending the same
opening signal again during the hold-open time. This function
is usually implemented with OP doors.
Disabled X No interruption of the hold-open time.
Enabled Hold-open time can be interrupted with one of the signals from
the same group:
Group 1: AKI button, AKA button
Group 2: AKI button reduced, AKA button reduced
Group 3: SSK
▪ The interruption only works with the signals listed above.
DRIVE
→ Reduced opening width 40 This parameter sets the opening width when the door operates
with reduced opening width. This operating mode can be acti-
vated by the operator through a control unit and saves energy.
0 = minimum opening width
40 = total opening width
▪ A reduced opening width of 40 corresponds to the full
opening width, as it has been determined during the door
learning cycle.
▪ The reduced opening width is only carried out to the cor-
rect position after a first complete door movement has tak-
en place.
▪ The minimum opening width is not allowed to fall below an
opening width of 10 cm per door leaf.
▪ In case of security-relevant door openings (SÖK, EMER-
GENCY OPENING, etc.) and certain door types (e.g.
DEAD MAN) the door always opens completely.
▪ A comfortable setting option is available in the
Continuous-
ly open
operating mode. Any change in the setting is im-
mediately taken over and the door automatically slides to