1. DISPLAY: 5 digit LCD 0.48" (12.2 mm) high digits
CUB5TCR0: Reflective LCD with full viewing angle
CUB5TCB0: Transmissive LCD with selectable red or green LED backlight,
viewing angle optimized. Display color change capability with output state
when using an output module.
2. POWER: Input voltage range is +9 to +28 VDC with short circuit and input
polarity protection. Must use an RLC model MLPS1 or a NEC Class 2 or
SELV rated power supply.
3. READOUT:
Resolution: 1 or 0.1 degrees
Scale: °F or °C
Offset Range: -999 to 9999 display units
4. THERMOCOUPLE INPUTS:
Isolation: TC+ and TC- terminals are not electrically isolated from the power
supply or optional comms cards.
Response Time: 500 msec.
Open Sensor Display:
Overrange/Underrange Input: /
Overrange/Underrange Display : “.....”/“-.....”
Maximum Input Voltage: 30 VDC, TC+ to TC-
Maximum Input Voltage TC-: 3 VDC max. with respect to common
*After 20 min. warm-up. Accuracy is specified in two ways: Accuracy over
an 18 to 28°C and 15 to 75% RH environment; and Accuracy over a -35 to 75°C
and 0 to 85% RH (non condensing) environment. Accuracy specified over the 0
to 50°C operating range includes meter tempco and cold junction tracking
effects. The specification includes the A/D conversion errors, linearization
conformity, and thermocouple cold junction compensation. Total system
accuracy is the sum of meter and probe errors. Accuracy may be improved by
field calibrating the meter readout at the temperature of interest.
5. USER INPUT (USR): Programmable input. Connect terminal to common
(USR COMM) to activate function. Internal 10KΩ pull-up resistor to +9 to 28
VDC.
Threshold Levels: V
IL
= 1.0 V max; V
IH
= 2.4 V min; V
MAX
= 28 VDC
Response Time: 5 msec typ.; 50 msec debounce (activation and release)
6. CERTIFICATIONS AND COMPLIANCES:
7. MEMORY: Nonvolatile E
2
PROM memory retains all programming
parameters and max/min values when power is removed.
8. ENVIRONMENTAL CONDITIONS:
Operating Temperature Range for CUB5TCR0: -35 to 75°C
Operating Temperature Range for CUB5TCB0 depends on display color
and intensity level as per below:
Storage Temperature: -35 to 85°C
Operating and Storage Humidity: 0 to 85% max. relative humidity (non-
condensing)
Altitude: Up to 2000 meters
9. CONNECTIONS: Wire clamping screw terminals
Wire Strip Length: 0.3" (7.5 mm)
Wire Gage: 30-14 AWG copper wire
Torque: 5 inch-lbs (0.565 N-m) max.
10. CONSTRUCTION: This unit is rated for NEMA 4X/IP65 requirements for
indoor use. Installation Category I, Pollution Degree 2. High impact plastic
case with clear viewing window. Panel gasket and mounting clip included.
11. WEIGHT: 3.2 oz (100 g)
2
GENERAL METER SPECIFICATIONS
ORDERING INFORMATION
TYPE MODEL NO. DESCRIPTION PART NUMBER
CUB5 CUB5TC
CUB5TCB0
CUB5TCR0
Optional Plug-in Cards
CUB5SNK
CUB5RLY
CUB5COM
RS232 Serial Communications Card
RS485 Serial Communications Card
Dual Sinking Output Card
Single Relay Output Card
CUB5COM2
CUB5COM1
CUB5SNK0
CUB5RLY0
Accessories
SFCRD
CBLPRO
CBPRO
MLPS1
Crimson 2 PC Conguration Software for Windows 98, ME, 2000, XP
*
RS232 Programming Cable (DB9-RJ11)
RS485 Programming Cable (DB9-RJ11)
Micro-Line Power Supply, 85 to 250 VAC
SFCRD200
CBLPROG0
CBPRO007
MLPS1000
Thermocouple Meter with Backlight Display
Thermocouple Meter with Reective Display
MODEL
NO.
DISPLAY COLOR
INPUT CURRENT
@ 9 VDC WITHOUT
CUB5RLY0
INPUT CURRENT
@ 9 VDC WITH
CUB5RLY0
CUB5TCR0 --- 10 mA 40 mA
CUB5TCB0 Red (max intensity) 85 mA 115 mA
CUB5TCB0 Green (max intensity) 95 mA 125 mA
TEMPERATURE
1 & 2 -35 to 75°C
3 -35 to 70°C
4 -35 to 60°C
5 -35 to 50°C
1 & 2 -35 to 75°C
3 -35 to 65°C
5
4
-35 to 35°C
-35 to 50°C
INTENSITY LEVEL
Green Display
*Crimson 2 software is a free download from http://www.redlion.net/
Red Display
TC TYPE RANGE
ACCURACY
@ 23°C
±°C
WIRE COLOR
5.8
4.3
15.0
ANSI
BS 1843
T
-200 to 400°C
-328 to 752°F
2.3
(+) blue
(-) red
(+) white
(-) blue
J
-200 to 760°C
-328 to 1400°F
1.9
(+) white
(-) red
(+) yellow
(-) blue
R
0 to 1768°C
32 to 3214°F
4.5
no
standard
(+) white
(-) blue
S
0 to 1768°C
32 to 3214°F
4.5
no
standard
(+) white
(-) blue
B
200 to 1820°C
300 to 3308°F
9.1<540 °C
4.5>540 °C
no
standard
no
standard
E
-200 to 871°C
-328 to 1448°F
2.7
(+) purple
(-) red
(+) brown
(-) blue
N
-200 to 1300°C
-328 to 2372°F
2.8
(+) orange
(-) red
(+) orange
(-) blue
K
-200 to 1372°C
-328 to 2502°F
2.3
(+) yellow
(-) red
(+) brown
(-) blue
mV -10.00 to 60.00 0.02 mV
no
standard
no
standard
15.0
42.6<540 °C
15.0>540 °C
4.9
8.1
5.8
0.08 mV
DISPLAY
t
J
r
S
b
E
n
K
LIN
ACCURACY
@ -35 to 75°C
±°C
CE specifications pending.