1616
6.3 mOdule 3 - display and prOgram lOCK-OuT
parameTers ()
3-LOC
COdE
Lock-out
Rate Display
Factor x
Access
Scale
Count Load
Access
Counter x
Display
Lock-out
Counter x
Pro
Lock-out
Min Display
Lock-out
Max Display
Access
Setpoint 1-4
Security
Code
LO HI
SP-nCNt
PAR
rAtE CNtLd SCFAC
x
d-LEV
Display
Intensity
Access
PARAMETER MENU
x = Counter A , Counter B, and then Counter C
n = Setpoints 1 to 4
Module 3 is the programming for Display lock-out and “Full” and “Quick”
Program lock-out.
When in the Display Mode, the available displays can be read consecutively
by repeatedly pressing the DSP key. An annunciator indicates the display being
shown. These displays can be locked from being visible. It is recommended that
the display be set to when the corresponding function is not used.
“Full” Programming Mode permits all parameters to be viewed and
modified. This Programming Mode can be locked with a security code and/or
user input. When locked and the PAR key is pressed, the meter enters a Quick
Programming Mode. In this mode, setpoint, count load, scale factor values, and
the Display Intensity Level () parameter can still be read and/or changed
per the selections below.
COUNTER A B C DISPLAY LOCK-OUT
RATE DISPLAY LOCK-OUT
MAX. MIN. DISPLAY LOCK-OUT
These displays can be programmed for or .
to
The Count Load Values can be programmed for , , or .
The setpoint displays can be programmed for , , or (See the
following table). Accessible only with the Setpoint Plug-in card installed.
COUNT LOAD A B C ACCESS LOCK-OUT
The Scale Factor values can be programmed for , , or .
SCALE FACTOR A B C ACCESS LOCK-OUT
Entry of a non-zero value will cause the prompt to appear when trying to
access the “Full” Programming Mode. Access will only be allowed after entering
a matching security code or universal code of . With this lock-out, a user input
would not have to be configured for Program Lock-out. However, this lock-out is
overridden by an inactive user input configured for Program Lock-out.
SECURITY CODE
SETPOINT 1 to 4 ACCESS LOCK-OUT
PROGRAMMING MODE ACCESS
SECURITY
CODE
USER INPUT
CONFIGURED
USER INPUT
STATE
WHEN PAR KEY IS
PRESSED
“FULL” PROGRAMMING MODE ACCESS
0
not
———— “Full” Programming Immediate access.
>0
not
———— Quick Programming After Quick Programming with correct code # at prompt.
>0
Active Quick Programming After Quick Programming with correct code # at prompt.
>0
Not Active “Full” Programming Immediate access.
0
Active Quick Programming No access
0
Not Active “Full” Programming Immediate access.
Throughout this document, Programming Mode (without Quick in front) always refers to “Full” Programming (all meter parameters are accessible).
Shaded areas represent program access that is model dependent.
Shaded areas are model dependent.
Not visible in Display Mode
Visible in Display Mode
DESCRIPTIONSELECTION
Not visible in Quick Programming Mode
Visible and changeable in Quick Programming Mode
Visible but not changeable in Quick Programming Mode
DESCRIPTIONSELECTION
The Display Intensity Level can be programmed for
, , or .
DISPLAY INTENSITY ACCESS LOCK-OUT