3.8 Factory Settings
The Manager30 is shipped with a number of settings already programmed into
the unit. These settings are set to ensure that the charger will safely charge any
battery and may not reect the actual requirements for your battery type. It is
important to review these settings and adjust as required.
Setting Factory Value
Battery Type GEL
Capacity 40AH
Charge Mode TOURING
Key Tone Status ON
Contrast 50%
Brightness 90%
Backlight Timer 30 secs
Home Screen Timer 30 secs
Language English
Max Charge Current 30 Amps
Low SOC Alarm 10%
Low Voltage Alarm 10.5 Volts
Load Disconnect Off
DC Input Trigger Auto
Modication of the ‘Advanced Settings’ menu items affect the way The Manager30 unit responds to charging situations.
Modication of these settings may result in the unit not functioning at 100% of its capacity. These settings should only
be modied if absolutely necessary and when the effects of the changes are 100% understood.