This electric water heater complies with the requirements of EN 60335-1,
EN 60335-2-21.
PURPOSE OF USE
The appliance is designed to supply hot water to household facilities
equipped with a piping system operating with pressure not greater than 6.0
bar.
It is designed to operate only in closed and heated premises where the air
temperature is not lower than 4°C and it is not designed to operate
continuously.
TECHNICAL SPECIFICATIONS
Nominal volume - 6litres
Nominal voltage - 230-240V ac
Nominal power consumption - 1500 watts
Nominal pressure - 6.0bar
ATTENTION!
This is not the water mains pressure. This is the pressure that is
rated for the appliance and refers to the requirements of the safety
standards.
Water heater type closed accumulating water heater, with thermal insulation
Inner coating: Glass-ceramic
Daily energy consumption - see Annex I
Rated load profile - see Annex I
Quantity of mixed water at 40°C 6 litres - see Annex I
Maximum temperature of the thermostat - see Annex I
Default temperature settings - see Annex I
Energy efficiency during water heating - see Annex I
IMPORTANT RULES
DO NOT switch the electrical supply on to the water heater until you are
sure that it is filled with water.
A suitably qualified person must perform the connecting of the water
heater to the water supply.
A suitably qualified electrician must perform the connecting of the water
heater to the electric network, if the plug is not used. (See page 11 for
colour codes)
Connecting the water heater to the electric mains via a plug must only use
the plug supplied.
If the water-heater will not be used for longer than 3 days and the
temperature in the premises could drop below 4°C, the water in the water
heater must be drained to avoid any possible damage of the appliance.
3
IMPORTANTSAFETYINFORMATION
YourMS6Heaterhasbeendesignedforconvenience, economyandsafetyof
use,providedthatitisinstalled, usedandmaintainedingoodworkingorderand
in accordancewithourinstructionsand recommendations.
Allwiringandinstallationmustbesupervisedbya suitablyqualified person.
THISAPPLIANCEMUSTBEEARTHED.
Theinstallationmustbeinaccordancewith thecurrenteditionofBS.7671
(theIEEWiring Regulations”)andPartP”oftheBuildingRegulations” in
forceatthetimeofinstallation.Installationsoutside of EnglandandWales
mustalsoconformtoanylocal regulationsineffect.
Thisapplianceisintendedtobepermanently connectedtothefixedelectrical
wiringofthemains supplywithitsowndedicatedsupplyORusingthe plug
provided.
Ensurethatthemainswatersupplymeetsthe requirementslisted.
ThisapplianceMUSTNOTbefittedwhereitmaybe subjectedtofreezing
conditions.DONOTswitchthe applianceonifyoususpectitofbeingfrozen.
Wait untilyouaresureithasthawedout.
TheunitMUSTNOTbemountedupsidedown.
TheunitMUSTNOTbefittedtoanytypeof THERMOSTATICmixervalveor
tap.
The MUST BE fittedintheInletfeedto
the unit.
Isolatethemainselectricalandwatersupplybefore removingthefront cover
oftheappliance.
?
?
?
?
?
?
?
?
?6barPressure ReliefValve (supplied)
?
?
In ALL cases the DIELECTRIC JUNCTIONS MUST be connected to the
heater before any other connection is made. This is very important as
they prevent the heater against potential aggressive corrosion.