WHAT TO DO IF THINGS GO WRONG (1)
SELF HELP
If the unit is not working satisfactorily, make the following checks before calling out the installer.
Any one of these adjustments could restore the performance.
Symptom
Cause
What to do
Little or no water flow.
The main water supply is turned
off.
Turn on the main supply fully at the
stop valve. Set up unit as per
commissioning instructions.
Cold water only
- neon light off.
The main water supply is not
turned on enough.
Turn on the main supply fully at the
stop valve.
Water too cold
- neon light on.
The water flow rate is too high.
The inlet water temperature has
dropped.
Adjust the service valve (see page 8).
Adjust the service valve (see page 8).
For a shower, adjust the spray pattern
available on the multi-mode handset.
Water flow too low, or
temperature too high.
The main water supply is too low
The hot tap is not fully open.
Increase the supply water flow.
Make sure that the service valve is
correctly adjusted.
Adjust the service valve so that the
water is at the right temperature with
the tap fully open (see page 8).
Always turn the hot tap fully on.
Water goes from hot
to cold.
The water flow or pressure is too
low, and the thermal cut-out is
operating.
A second outlet has been turned
on.
Increase the supply water flow
Make sure that the service valve is
correctly adjusted.
Do not use the basin whilst using the
shower.
Shower spray pattern
deteriorates.
The shower handset is clogged.
Clean the handset using a descaling
solution if required.
REDRING AFTER SALES SERVICE
We offer a technical advisory service on the telephone to installers and other customers with
problems in the field.
Ring 0344 8793588 Or alternatively email us on:
GDHV.customersupport@glendimplex.com
Remember to quote the exact type of unit, as written on the front of the unit and on this leaflet.
The model and serial number are located on the bottom face of the unit.
Make a note of those numbers here and be sure to quote them if you call for advice.
Model Number: _ _ _ _ _ _ _ _ _ _ _ _ _
Serial Number:
_ _ _ _ _ _ _ _ _ _ _ _ _ _ _
Note: You may be charged for a service call if you do not have the serial number.

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Redring POWERSTREAM RPS95 and is the answer not in the manual?

Redring POWERSTREAM RPS95 Specifications

General IconGeneral
BrandRedring
ModelPOWERSTREAM RPS95
CategoryWater Heater
LanguageEnglish

Related product manuals