3.2.1.2 (If your machine is matched with water chiller)
Figure 2 (2-2)
Note:
1:water inlet 2:water outlet 3:air pipe 4:Air plug(signal input) 5:water outlet(water
chiller) 6:water inlet(water chiller) 7 air pump outlet 8:Air plug(signal output) 9:
power input 220V 10:water inlet(water chiller) 11:water outlet 12.Signal cable for water chiller
13.Water Pipe(2 pcs) 14.Air Pipe
Step:13(1--5) 13(2--6 ) 14(3--7) 12(4--8)
3.2.1 Connection of water pipe, air pipe, air pump and water cooler
1) Please make the water chiller full of 3/4 water.
2) Please connect the water pipe, air pump and signal wire with the connectors at the
back of the machine according to the above Figure
3.2.2 Functions of accessories:
(1) Function of air pump:
To prevent smoke dusts which were generated in the processing of materials into the
gas nozzle to pollute the focus lens
Blow away the dust, avoid the different depth in the processing.
(2) Function of Water Chiller:
Before machine working, please do make sure there is full of recycled water in the laser
tube, otherwise, it will damage the laser tube and can not be repaired. Please do keep the
water clean before you put it in the water cooler, dirty water will have bad effect on the
laser, and decrease the life of laser tube (Pure water is recommended). At the same time,