REFUsol 20K-2T (853P020.200)
User manual
- 53 -
confirmation; Press the up or DOWN button to change the size of the value, and
then long press the DOWN button to complete the input of the current value, and
enter the setting of the next value. After setting the fourth number, long press the
DOWM button to confirm, the value selection of antiReflux power can be
completed.
Note:Explanation of professional terms:
CTR Totalpower:The Sum of three-phase selling power of the connection point <=
The set Reflux power
CTR Phasepower:The sum of the three phase power vector of the connection point
= The set Reflux power
CTR SellingPower:The selling power of any phase of the system connection point
<=The set Reflux power /3
Selling electricity: sending electricity to the grid
Buy electricity: take energy from the grid
Anti-Reflux: limit the energy sent to the grid
Positive power: the power purchased
Negative power: the power of selling electricity