ST 0, STR 0 7
1.8 Basic specifications
1.8.1 Basic EA specifications
Max. load thrust [N], switch-off thrust [N], operating speed [mm/min], operating stroke [mm] and
electric motor parameters are given in Table 1.
Table 1: Basic Specifications
Operating
stroke
Electric motor
1)
Type/ type number
Operating speed
±10[%]
without
transmitter
with
transmitter
Max. load
thrust
for STR.
Max. load
thrust
for ST
Switch-off
Thrust
±10 [%]
Weight
Power supply
nominal voltage
Nom.
power
Nom.
speed
Men.
current
Capacitor
capacity.
[mm/min] [mm] [mm] [N] [N] [N] [kg]
[V] ±10%
[W] [1/min] [A] [μF/V]
1 2 3 4 5 6 7 8 9 10 11 12 13 14
3 200 4 000 4 500
2 560 3 200 3 800
1 280 1 600 1 900
5
640 800 950
3 200* 4 000* 4 500*
2 560 3 200 3 800
1 280 1 600 1 900
10
640 800 950
2 000* 2 500* 2 900*
1 280 1 600 1 900
16
640 800 950
1 280 1 600 1 900
20
640 800 950
640 800 950
504 630 725
40
16;
25;
28;
40*
8;
10;
12,5;
16;
20;
25;
28
256 320 360
2,75 375
0,04
(0,40)
0,27
16 504 630 725
24 V DC
6 3100 0,6 -
* For U
N
– 10% stands: F
(UN-10%)
= F.0.9
For –25°C stands: F
(-25°C)
= F.0.9
1) Switching elements for different type of load (also for EA) defines standard EN/IEC 60 947-4-1