Form: 640188 TS-8
Video System activates but not all
the monitors power-up. Green LED
on the rear of the monitor is off.
Power wire to non-
functioning monitor(s)
defective or improperly
connected.
Activate the Video System. Access
the power connector, attached to the
slide bracket, (561004). Verify
connection and measure Voltage. If
there is not 24 Volts present, trace
back the appropriate power cable and
verify connection and look for signs
of damage. Repair or replace cable
as necessary.
Monitor (700182) or Slide
Bracket (561004)
Defective.
If previous power checks are OK,
verify that the circuit breaker
(located on the rear of the monitor) is
not tripped. Reset if necessary.
Remove a functioning monitor from
another location and remove suspect
monitor and replace it with known
good unit. If unit now functions
replace or repair suspect unit. If unit
still does not operate verify the slide
bracket connections and repair or
replace unit as necessary.