REMKO PGT
Unit description
The units are mobile fan-assisted
air heaters (WLE) directly fired
with liquid gas, without a heat
exchanger.
The units operate without
an exhaust gas connection
and are designed exclusively
for commercial use.
The units are equipped with
integrated power regulation
for the stepless control of
the heating capacity, quiet and
low-maintenance axial fans,
robust gas burners with thermal
flame monitoring, electric solenoid
valves, electric ignition, room
thermostat socket and mains cable
with earthed safety plug.
The units conform to
the fundamental health and safety
requirements of the appropriate
EU stipulations and are simple
to operate.
The units are EC type-tested,
DVGW-registered and approved
for EU countries.
The units may be used among
other things for the following:
■
Drying newly completed
buildings
■
Spot heating of outdoor
workplaces
■
Spot heating workplaces
in open, non-flammable
manufacturing facilities and
halls
■
Temporarily heating enclosed
spaces with a sufficient fresh
air supply
■
De-icing machines, vehicles and
non-combustible warehoused
goods
■
Maintaining the temperature
of frost-sensitive parts
Safety notes
The units have been subjected
to extensive material, functional
and quality inspections prior to
delivery. However, dangers can
arise from the units if they are used
improperly or not as intended by
untrained personnel!
Please observe the following
information:
■
The units may only be operated
by persons that have been
instructed in their operation
■
The power plug must be pulled
out of the mains socket before
maintenance and repair work
■
The units must be installed such
that they are stable on a non-
combustible surface
■
It is necessary to ensure that no
flammable objects or materials
can be drawn in
■
The units must be installed and
operated in such a way that
personnel are not endangered
by exhaust gases and radiant
heat and no fires may occur
■
Portable liquid gas tanks must
be installed such that they are
stable and upright
■
Liquid gas tanks must never
be used whilst lying horizontal
during unit operation
■
All unit electrical cables must be
protected against damage, e.g.
by animals
Always observe the respective local building code and fire prevention
guidelines as well as the guidelines of the accident prevention
and insurance associations when using the units.
■
The units must then only
be operated in areas where
the units can be supplied
with an adequate amount
of air for combustion
■
The units must only be operated
in well-ventilated spaces and
away from flammable materials.
Personnel must not remain in
the installation area
Appropriate prohibition
signs should be put up
at the entrances!
■
A safety zone of 1.5 m must be
maintained around the units,
incl. to non-combustible items
■
A minimum distance of 3 m must
be maintained from the unit
outlet
■
The unit outlet must not
be restricted or fitted with hoses
or pipes
■
Never insert foreign objects
in the unit
■
The air intake grille must always
be kept free of dirt and loose
objects
■
The units must not be exposed
to direct jets of water
e.g. pressure washers, etc.
CAUTION
The units must not be used
for heating living spaces
in residential buildings.