NOTICE!
The hot water tank is produced from enamelled
steel. This is designed for standard quality
drinking water
. If drinking water with above-
average aggressive qualities is used (chloride
content ³ 150 mg/l) then it is not possible to
provide a guarantee unless special protective
measures are implemented!
Check and replace the magnesium anode
Checks
Allow the hot water tank to cool before performing
any maintenance work.
Perform maintenance yearly (in accordance with
DIN EN 8065, Annex A, T
able A1, row 42).
Check the magnesium anode yearly.
NOTICE!
Check the false anode regularly and have this
replaced by your fitter if necessary
. This is a
prerequisite for the guarantee!
It is replaced differently depending on the tank type
or anode design.
When installing replacement anodes, they may
have to be shortened to the corresponding tank
height.
NOTICE!
It is essential to replace the magnesium-false
anode if this exhibits a diameter of just 6-10
mm!
Replacement
Replace as follows:
1. Switch the REMKO RBW hot water heat
pump of
f.
2. Drain the storage tank to the relevant height.
3. Unscrew the magnesium anode.
4. Seal the new magnesium anode in and install
it.
5. Fill the storage tank and check that the mag-
nesium anode is leak-tight.
6. Switch the REMKO RBW hot water heat
pump on.
A
Fig. 4: Replacing the magnesium anode