2.2 Product data
Average condition
Series
RBW 301
PV
RBW 301
PV
-S
Energy efficiency ratio A+
Load profile XL
Hot water preparation energy efficiency
(mean temperature period A20/W55)
% 154
Hot water preparation energy efficiency (A14/W35) % 145
Current consumption stand-by kW 0,037
Yearly energy consumption Q
HE
(average)
1)
kWh 1087
Factory temperature setting °C 50
Inside sound power level dB(A) 57,9
Product data for water heaters with heat pump according to delegated regulation (EU) 812/2013
Name of supplier:
REMKO
GmbH & Co. KG
Supplier model identifier:
RBW 301
PV
RBW 301
PV
-S
Energy efficiency ratio (average climatic conditions) A+
Load profile XL
Hot water preparation energy efficiency
(average climatic conditions A7/W55)
% 130.6
Yearly energy consumption (average climatic conditions)
1)
kWh 1282
Sound power level L
W
A
, inside/outside
dB(A) 57
Factory delivery temperature setting °C 50
Hot water preparation energy efficiency ratio (colder A2/W55 / warmer
A14/W55 climatic conditions)
% 119/145
Yearly energy consumption (colder A2/W55/warmer A14/W55 climatic
conditions)
kWh 1405/1158
Heat losses W 44
Volume of mixed water at 40 °C L 347
Storage volume RBW/PV/RBW PV-S L 287/280
1)
The specified value is based on results from standard testing.
The actual consumption depends on the use and location of the unit
When assembling, installing or maintaining the water heater, pay particular attention to the following:
The electrical installation is to be carried out exclusively by trained or certified personnel. The
refrigeration maintenance and service is to be carried out only by qualified persons. For main-
tenance and opening of the heat pump, the mains supply line is to be disconnected from the
power supply
.
9