10 Shutdown
NOTICE!
Never switch of
f the equipment by pulling out
the mains plug.
Temporary shutdown
If it is planned to shut down the unit for longer
periods e.g. during the winter
, proceed as follows:
1. Let the unit run for 2-3 hours in circulation
mode. This extracts any residual humidity
from the unit.
2. Put the unit out of operation by pressing the
"I / 0" key on the operating panel. Only then
should you pull out the mains power plug and
wind up the cable.
3. Drain the internal condensation tank through
the condensation drainage hose at the rear
of the indoor unit.
4. Make sure that there is no condensate water
in the outdoor unit before storing the indoor
and outdoor unit indoors. T
o drain the con-
densate water, remove the stopper from the
outdoor unit.
NOTICE!
If indoor storage is not possible through the
winter due to the fixed installation method, the
outdoor unit can remain installed outdoors even
in frosty conditions. Note that in doing so, all
condensate must be removed from the con-
denser and this must be protected from the
influences of the winter weather with a tarpaulin
or film sheeting before the winter sets in. How-
ever
, never operate the unit when the outside
temperature is < 5 °C.
(see application area technical data!)
5. Clean the filter and the plastic surfaces.
6. Attach the outdoor unit to the indoor unit.
7. Cover the unit with a synthetic tarpaulin to
protect it against dust.
8. Store the unit in a cool and dry location away
from direct sunlight.
Permanent shutdown
The entire system should only be dismantled by a
specialist firm familiar with all environmental
aspects involved. REMKO GmbH & Co. KG or your
contractual partner will be pleased to provide a list
of refrigerant specialists in your area.
21