Heating capacity RVT 352
0,00
1,00
2,00
3,00
4,00
5,00
12 7 2 0 -7 -10 -15
2
1
3
A
[°C]
Fig. 6: Characteristic curves heating RVT 352 (specification at indoor temperature 20 °C)
A: Outdoor temperature
1: COP
2: Heating capacity in kW
3: Power consumption in kW
Outdoor temperature in °C 12 7 2 0 -7 -10 -15
Heating capacity in kW 4,21 3,70 3,53 3,35 2,98 2,80 2,42
Power consumption in kW 0,93 0,91 1,53 1,44 1,35 1,35 1,27
COP 4,55 4,07 2,31 2,33 2,21 2,08 1,90
Cooling capacity RVT 352
0,00
1,00
2,00
3,00
4,00
5,00
21 25 30 35 40 45 50
2
1
3
A
[°C]
Fig. 7: Characteristic curves cooling RVT 352 (specification at indoor temperature 27/19 °C)
A: Outdoor temperature
1: EER
2: Cooling capacity in kW
3: Power consumption in kW
Outdoor temperature in °C 21 25 30 35 40 45 50
Cooling capacity in kW 3,57 3,81 3,84 3,70 3,18 3,01 2,93
Power consumption in kW 0,92 0,99 1,08 1,18 1,20 1,22 1,26
EER 3,89 3,84 3,56 3,14 2,65 2,47 2,32