Loading...
Heating capacity RVT 522
0,00
1,00
2,00
3,00
4,00
5,00
6,00
7,00
12 7 2 0 -7 -10 -15
2
1
3
A
[°C]
Fig. 8: Characteristic curves heating RVT 522 (specification at indoor temperature 20 °C)
A: Outdoor temperature
1: COP
2: Heating capacity in kW
3: Power consumption in kW
Outdoor temperature in °C 12 7 2 0 -7 -10 -15
Heating capacity in kW 5,84 5,13 4,89 4,64 4,13 3,88 3,35
Power consumption in kW 1,30 1,28 2,15 2,02 1,89 1,89 1,79
COP 4,49 4,01 2,27 2,29 2,18 2,05 1,87
Cooling capacity RVT 522
0,00
1,00
2,00
3,00
4,00
5,00
6,00
21 25 30 35 40 45 50
2
1
3
A
[°C]
Fig. 9: Characteristic curves cooling RVT 522 (specification at indoor temperature 27/19 °C)
A: Outdoor temperature
1: EER
2: Cooling capacity in kW
3: Power consumption in kW
Outdoor temperature in °C 21 25 30 35 40 45 50
Cooling capacity in kW 4,92 5,25 5,30 5,10 4,38 4,15 4,04
Power consumption in kW 1,21 1,30 1,42 1,55 1,57 1,60 1,66
EER 4,08 4,03 3,73 3,29 2,78 2,59 2,43