I) Charger
Here the user can set the parameters of charger; the inverter is compatible with Lead acid and
lithium batteries. Users can set the battery type, charge and discharge parameters, awaken
mode here.Press up or down button to select and press”OK” to confirm. For the detailed
parameters, please refer to below table.
The remaining capacity of the battery when
inverter is working in online mode.
When the battery voltage reached this value,
the system will stop charging the battery.
When the inverter is working in online mode the
battery voltage reached this value, the system
will stop discharging the battery.
For lead acid battery, when charging begins, it
will enter constant voltage charging mode in
order to accelerate charging speed. The value
can be set for 50-58V.
For lead acid battery, it will switch to float
charging mode after exiting constant voltage
charging mode. The value can be set for 50-
58V.
The charge current can be set for 0-60A. The
charge power can also be set.
The discharge current can be set for 0-60A. The
charge power can also be set.
NOTE!
Please confirm the Inverter setting for maximum charge/discharge current is
within the range of battery rated charge/discharge current.