EasyManua.ls Logo

Renac ESC5000-DS - Page 37

Default Icon
46 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
37
I) Charger
Here the user can set the parameters of charger; the inverter is compatible with Lead acid and
lithium batteries. Users can set the battery type, charge and discharge parameters, awaken
mode here.Press up or down button to select and pressOK to confirm. For the detailed
parameters, please refer to below table.
Parameter
Comment
Min capacity
The remaining capacity of the battery when
inverter is working in online mode.
Charge Cut Voltage
When the battery voltage reached this value,
the system will stop charging the battery.
Discharge Cut Voltage
When the inverter is working in online mode the
battery voltage reached this value, the system
will stop discharging the battery.
Charge Absorb Voltage
For lead acid battery, when charging begins, it
will enter constant voltage charging mode in
order to accelerate charging speed. The value
can be set for 50-58V.
Charge Float Voltage
For lead acid battery, it will switch to float
charging mode after exiting constant voltage
charging mode. The value can be set for 50-
58V.
Charge Max Current
The charge current can be set for 0-60A. The
charge power can also be set.
Discharge Max Current
The discharge current can be set for 0-60A. The
charge power can also be set.
NOTE!
Please confirm the Inverter setting for maximum charge/discharge current is
within the range of battery rated charge/discharge current.

Related product manuals