Two machine outputs (for three probes)
Three machine outputs (Dedicated start)
Three machine outputs (Common start / pulsed mode )
Three machine outputs (Common start / level mode)
Probe start-up time = 410 ms max. for kinematic probes and
1 s max. + delay (10, 50, 100 ms) for strain gauge probes.
Probe start-up time = 410 ms max. for kinematic probes and
1 s max. for strain gauge probes.
Probe start-up time = 410 ms max. for kinematic probes and
1 s max. for strain gauge probes.
Probe start-up time = 410 ms max. for kinematic probes and
1 s max. for strain gauge probes.
Machine start
input 1
Machine start
input 1
Machine start
input 1
Machine start
input 1
Machine start
input 2
Machine start
input 2
Machine start
input 2
Machine start
input 2
Machine start
input 3
Machine start
input 3
Machine start
input 3
Start
Stop
Stop
10, 50, 100 ms
delay options
Probe 1
Probe 1
Probe 1
Probe 1
Probe 2
Probe 2
Probe 2
Probe 2
Probe 3
Probe 3
Probe 3
Probe 3
Multiple probe mode timing diagrams
Start
Stop
Start
Start
Stop
Start
Stop
Start
Stop
Start
Stop
Start
Stop
Start
Stop
Start
Stop
Start
Stop
Start
Stop
Start
Stop
Start
Stop
Start
Stop
Start
Stop
10, 50, 100 ms
delay options
OSI/OSI-D with OMM-2C installation guide
2.10
OMM-2C basics

Table of Contents