Battery Safety
Use only sealed lead-acid, flooded, gel or lithium batteries which
must be deep cycle.
Explosive battery gases may be present while charging. Be certain there is enough
ventilation to release the gases.
Be careful when working with large lead acid batteries. Wear eye protection and have
fresh water available in case there is contact with the battery acid.
Over-charging and excessive gas precipitation may damage the battery plates and
activate material shedding on them. Too high of an equalizing charge or too long of one
may cause damage. Please carefully review the specific requirements of the battery
used in the system.
Equalization is carried out only for non-sealed / vented/ flooded / wet cell lead acid
batteries.
Do
NOT
equalize VRLA type AGM / Gel / Lithium cell batteries UNLESS permitted by
battery manufacturer.
Carefully read battery manuals before operation.
Do
NOT
let the positive (+) and negative (-) terminals of the battery touch each other.
Connect battery terminals to the charge controller BEFORE connecting
the solar panel(s) to the charge controller. NEVER connect solar panels to
charge controller until the battery is connected.
Do NOT connect any inverters or battery charger into the load terminal of
the charge controller.
Once equalization is active in the battery charging, it will not exit this stage
unless there is adequate charging current from the solar panel. There
should be NO load on the batteries when in equalization charging stage.
WARNING
Recycle battery when it is replaced.

Other manuals for Renogy ROVER Series

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Renogy ROVER Series and is the answer not in the manual?

Renogy ROVER Series Specifications

General IconGeneral
Temperature Compensation-3mV/°C/2V(Default)
TypeMPPT
Nominal System Voltage12V/24V Auto
Rated Charge Current20A, 30A, 40A, 60A
Max PV Input Voltage100V (20A/30A), 150V (40A/60A)
Max Solar Input Power260W (12V)/520W (24V) for 20A, 390W (12V)/780W (24V) for 30A, 520W (12V)/1040W (24V) for 40A
Battery TypeSealed, Gel, Flooded, Lithium
CommunicationRS232
ProtectionOver Heating