INSTRUCTIONS FOR USE
1. Install the batteries.
2. Press the On/Off switch on the bottom of the Wee
Sight to turn the unit ON.
3. Place the Wee Sight on a flat surface or hold in
your hand, then place the patient’s hand, palm down,
over the top of the Wee Sight and LED.
NOTE: To improve vein location and view, tighten the
skin by draping the patient’s fingers over the Wee
Sight.
4. Dim the room lights for better illumination.
5. Insert the IV catheter, then turn the Wee Sight OFF
by pressing the On/Off switch.
WARNING
LED radiation. DO NOT stare into beam. Class 2 LED product.
CAUTIONS
Do not submerge the Wee Sight into liquids.
Do not place liquids near the device.
Do not mix battery types. For replacement, use only AA alkaline batteries.
Do not recharge non-rechargeable batteries.
NOTES
Discard device upon failure of an LED and/or the On/Off switch.
Dispose of the device in accordance with local regulations.
Clean the Wee Sight in accordance with the standard hospital protocol for
cleaning.
Replace batteries upon degradation of the device functionality.
Batteries are the only serviceable parts. Children’s Medical Ventures
recommends replacing both batteries at the same time.
The Wee Sight
TM
is a portable, LED, battery-operated device that is intended to
assist in locating veins in the patient’s extremities.
Transilluminator
Item 1017920
Caution: US federal law restricts this device to sale by or on the order of a
physician.
On/Off Switch
Battery Door
INSTRUCTIONS FOR USE
THE HEART OF DEVELOPMENTAL CARE
SM
Question and Answer IconNeed help?

Do you have a question about the Respironics Wee Sight 1017920 and is the answer not in the manual?

Respironics Wee Sight 1017920 Specifications

General IconGeneral
Product TypePulse Oximeter
BrandRespironics
Measurement ParametersSpO2, Pulse Rate
Pulse Rate Range30-250 bpm
Model1017920
Patient TypePediatric
Display TypeDigital
Accuracy±2 digits
Power SourceBattery
WeightUnknown
DimensionsUnknown

Summary

Instructions for Use

General Safety and Handling

Includes warnings about LED radiation, cautions for liquid exposure, battery types, and notes on device maintenance and disposal.

Specifications

Battery Type

Specifies the required battery type for the device.

Electric Shock Protection

Details the type of protection against electric shock provided by the device.

Output Light Wavelength

Indicates the wavelength of the light emitted by the device.

Related product manuals