36
Err 38 Thermistor short-circuited. Contact an authorised
service company.
Err 40 Outage of the chamber
thermal fuse, boiler (only
boiler combi ovens), draught
interrupter (only gas combi
ovens with adraught
interrupter) or switchboard
thermal fuse.
Contact an authorised
service company.
Err 41 Cooling error - overheating
of electronics.
Clean the dust filter.
If the error occurs
repeatedly, please contact
an authorised service
company.
Err 42 Overheating of the boiler
heating element.
The combi oven will
automatically switch to the
reserve injection state and
it is possible to continue
using it. After the combi
oven is turned o and then
on again, it will attempt
to put the boiler into
operation. If the problem
reoccurs, please contact
an authorised service
company.
Err
60-79
Modbus communications
error.
Disconnect the power
supply to the combi oven
(not “Standby” mode), wait
30 seconds and then turn
on the combi oven again
(reconnect the power
supply). If the problem
reoccurs, please contact
an authorised service
company.
Err
80-91
Frequency converter error. If the problem reoccurs,
please contact an
authorised service
company.
Err
95/97
Incorrect blower speed. If the problem reoccurs,
please contact an
authorised service
company.
Err
96/98
Lighting up error. Check that the gas supply
is open and reattempt
to start cooking. If the
problem reoccurs, please
contact an authorised
service company.
User’smanual | Orange Vision Combi Ovens I08 ERROR MESSAGE TABLE
Equipment failures can be repaired by authorized service only,
which is trained and certified by the manufacturer. Warranty does
not apply in the case of improper or unauthorized service!
Combi oven must be subjected to regular checks throughout the
operation, tests and revisions as required by ČÚBP č. 48/1982 Coll.