8 I ERROR MESSAGE TABLE
There could apear error messages on the display during the cooking
process. Their meaning is as follows:
Err 18 When draining the boiler,
the water level did not fall
below the maximum water
level within the set time
limit.
The combi oven will
automatically switch to the
reserve injection state and
it is possible to continue
using it temporarily. After
the combi oven is turned
o and then on again, it
will attempt to put the
boiler into operation. If the
problem reoccurs, please
contact an authorised
service company.
Err 26 Flap valve error. The
automatic flap valve is not
working correctly.
Incorrect function of
the flap valve may aect
cooking results, however,
it is possible to continue
using the combi oven
temporarily. Contact
an authorised service
company.
Err 31 Drain heat sensor error. The combi oven can
temporarily be used
in all modes. Contact
an authorised service
company.
Err 32 Boiler heat sensor error. The combi oven will
automatically switch to the
reserve injection state and
it is possible to continue
using it temporarily. After
the combi oven is turned
o and then on again, it
will attempt to put the
boiler into operation. If the
problem reoccurs, please
contact an authorised
service company.
Err 34 Error of the 1-point
temperature probe.
The combi oven can
temporarily be used
in all modes with the
exception of the modes
with atemperature probe.
Contact an authorised
service company.
Err 35 Chamber heat sensor error. Error blocks work in
all modes. Contact
an authorised service
company.
Err 36 Error of the 6-point
temperature probe.
The combi oven can
temporarily be used
in all modes with the
exception of the modes
with atemperature probe.
Contact an authorised
service company.
Err 37 Thermistor disconnected. Contact an authorised
service company.
ERROR DESCRIPTION SOLUTION
Err 10 The minimum water level
was not reached in the
boiler within the set time
limit despite the maximum
water level being reached.
The combi oven will
automatically switch to the
reserve injection state and
it is possible to continue
using it temporarily. After
the combi oven is turned
o and then on again, it
will attempt to put the
boiler into operation. If the
problem reoccurs, please
contact an authorised
service company.
Err 11 Chamber heating element
error.
The combi oven cannot
continue operating.
Contact an authorised
service company.
Err 12 The maximum water level
was not reached in the
boiler within the set time
limit.
The combi oven will
automatically switch to the
reserve injection state and
it is possible to continue
using it temporarily. After
the combi oven is turned
o and then on again, it
will attempt to put the
boiler into operation. If the
problem reoccurs, please
contact an authorised
service company.
Err 13 The minimum water level
was not reached in the
boiler within the set time
limit.
Check the water supply
inlet (open tap). The
combi oven can be used
temporarily only in hot
air mode. If the problem
reoccurs, even when water
supply is provided, please
contact an authorised
service company.
Err 15 Failure of motor heat
protection. Signals motor
overheating above the set
limit.
Kontaktujte autorizovanou
servisní firmu.
Err 16 The boiler was not
preheated within the set
time limit.
The combi oven will
automatically switch to the
reserve injection state and
it is possible to continue
using it temporarily. After
the combi oven is turned
o and then on again, it
will attempt to put the
boiler into operation. If the
problem reoccurs, please
contact an authorised
service company.
Err 17 When draining the boiler,
the water level did not fall
below the minimum water
level within the set time
limit.