1. AUTO Mode (Default)
• Dispense the Preset amount (Small / Medium / Large) 0.5 seconds after the cup
detection and stops automatically.
2. MANUAL Mode
• On Manual Mode, no LED light will be lit even if a cup is inserted.
• Double press the START button to start dispensing. It will automatically stop when the
Preset amount(Small / Medium / Large ) is dispensed like the AUTO Mode.
AUTO / MANUAL Mode
• AUTO / MANUAL : Press Up and Down button to select AUTO or MANUAL.
AUTO
MANUAL
FLOW SENSOR Mode
A function to enclose the gap between the Preset volume and the actual dispensed
volume.
• Coefficient : Press Up and Down button to adjust the value. (Default : 1.15)
- If the actual volume is more than the Preset volume : Lower the coefficient.
- If the actual volume is less than the Preset volume : Raise the coefficient.
It is recommended to adjust from the second digit after the decimal.
• Flow rate : This shows the flow rate measured in Preset Mode. (Default : 62.5mL/s)
.
FLOW SENSOR
Coefficient : 1.15
19