EasyManua.ls Logo

Reznor X - User Manual

Reznor X
32 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
Loading...
Form I-X, P/N 150491 R7, Page 1
Applies to: Model X
Indoor Duct Furnace
Form I-X (Version D)
Obsoletes Form I-X (Version C)
Installation / Operation / Maintenance
A
G
E
N
C
Y
P
R
O
C
E
S
S
S
T
A
R
T
-
U
P
P
R
O
D
U
C
T
C
U
S
T
O
M
E
R
W
A
R
R
A
N
T
Y
C
O
N
V
E
R
G
E
N
T
Q
U
A
L
I
T
Y
S
Y
S
T
E
M
CQS
CQS
!
WARNING:
FIRE OR EXPLOSION HAZARD
Failure to follow safety warnings exactly could result in serious injury, death, or
property damage.
Be sure to read and understand the installation, operation, and service instructions in
this manual.
Improper installation, adjustment, alteration, service, or maintenance can cause
serious injury, death, or property damage.
Do not store or use gasoline or other ammable vapors and liquids in the vicinity
of this or any other appliance.
WHAT TO DO IF YOU SMELL GAS
Do not try to light any appliance.
Do not touch any electrical switch; do not use any phone in your building.
Leave the building immediately.
Immediately call your gas supplier from a phone remote from the building. Follow
the gas suppliers instructions.
If you cannot reach your gas supplier, call the re department.
Installation and service must be performed by a qualied installer, service agency,
or the gas supplier.

Questions and Answers

  • J
    Jill BrownAug 5, 2025
    What to do if Reznor X pilot lights but the main valve won't open (spark ignition)?
    • I
      iscottAug 5, 2025
      If the pilot light in your Reznor Furnace ignites, but the main valve refuses to open, here's what you can check: * Make sure the manual valve is fully open. * If 24 volts is measured at the valve connections and the valve remains closed, replace the defective valve. * Inspect all wiring connections, and tighten any loose connections. * Ensure the flame sensor lead isn't grounded, and the insulation or ceramic isn't cracked; replace as needed. * Set the supply pressure at 5" w.c. to 8" w.c. for natural gas and 11" w.c. for propane if the gas pressure is incorrect. * Replace the sensor if the ceramic is cracked. * If all checks indicate no other cause, replace the faulty ignition controller.
  • S
    Scott ElliottAug 11, 2025
    Why is my Reznor X delivering cold air on startup or during operation?
    • C
      Crystal HurstAug 11, 2025
      There are several reasons why your Reznor Furnace might be delivering cold air: * The fan control may be improperly wired; connect it according to the wiring diagram. * The fan control may be defective, requiring replacement. * The manifold pressure may be incorrect; check the manifold line pressure. * The blower may be set for too low a temperature rise; slow down the blower or increase static pressure.
  • E
    Elizabeth TurnerAug 15, 2025
    What to do if my Reznor Furnace pilot won't light (match-lit system)?
    • J
      jenniferhaynesAug 15, 2025
      If the pilot light of your Reznor Furnace with a match-lit system won't light, consider the following: * Ensure the manual valve is open. * Bleed the gas line to remove any air. * Clean the pilot orifice with compressed air or solvent, being careful not to ream it. * Check and adjust the gas supply pressure. * Replace any bent or kinked pilot tubing. * Replace the ECO device if it has failed.
  • A
    Ashley JacksonAug 20, 2025
    Why is my Reznor Furnace not producing heat even when it's operating?
    • P
      palmerwyattAug 20, 2025
      If your Reznor Furnace is running but not producing heat, consider these potential causes: * Dirty filters in the blower system can restrict airflow; clean or replace them. * Incorrect manifold pressure or orifices can affect combustion; check the manifold pressure. * The unit might be cycling on the limit control; check air throughput. * The thermostat might be improperly located or adjusted; consult the thermostat manufacturer's instructions. * The belt might be slipping on the blower; adjust the belt tension.
  • J
    Justin AlvarezOct 30, 2025
    How to fix Reznor X pilot that won't light with spark ignition?
    • D
      danielrichOct 30, 2025
      If the pilot light of your Reznor Furnace with spark ignition system won't light, there are several potential causes and solutions: * Ensure the manual valve is open. * Bleed the gas line to remove any air. * Clean the pilot orifice with compressed air or solvent, being careful not to ream it. * Check and adjust the gas supply pressure. * Replace any kinked pilot tubing. * If 24 volts are available at the pilot valve, replace the valve if it doesn't open. * Ensure all wire connections are secure. * Verify that 24 volts are available, and if not, address the transformer failure. * Maintain the spark gap at 7/64". * Replace any worn or grounded spark cable. * Replace the pilot if the ceramic spark electrode is cracked or grounded. * Ensure all panels are tightly secu...
  • X
    xalexanderNov 25, 2025
    What to do if Reznor X pilot lights but main valve won't open (match-lit system)?
    • S
      Stephanie CarneyNov 25, 2025
      If the pilot light of your Reznor Furnace with a match-lit system ignites, but the main valve won't open, check the following: * Ensure the manual valve is open. * Verify that the power is on, check the fuses, and ensure the thermostat is calling for heat. * Check the wiring and connections at the transformer and thermostat to ensure the circuit to the valve is not open. * Replace the transformer if it's faulty. * Clean and test the thermocouple or safety pilot switch, or test the ECO device; replace any defective parts. * Replace the thermostat if it's faulty. * Replace the valve or magnetic head if the valve is faulty. * Ensure the gas pressure is not too high; the maximum supply gas pressure should be 8 oz. or 14" w.c. * Correct any venting problems and reset the swit...

Summary

1.0 General

1.1 Hazard Labels and Notices

Explains hazard intensity levels and warnings for safety.

1.4 Installation Codes

Specifies installation compliance with national and local codes.

2.0 Furnace Location

6.0 Mechanical

6.1 Gas Piping and Pressures

Information on gas supply, pressure testing, and piping requirements.

6.1.2 Manifold or Orifice Pressure Settings

Instructions and warnings for setting manifold gas pressure for natural and propane gas.

6.2 Venting

General requirements for proper venting, clearances, and codes.

6.2.1 Venting Requirements

Further requirements for vent pipe, chimney connections, and height.

7.0 Electrical Supply and Wiring

7.1 General

Electrical wiring and grounding requirements based on codes.

7.2 Supply Voltage and Wiring

Guidance on supply voltage, current requirements, and wiring connections.

7.4 Typical Wiring Diagrams

Diagram for Model X furnace with spark pilot and single-stage gas valve.

8.0 Controls

8.2 Limit and Energy Cutoff Controls

Details on high limit and ECO controls and potential causes of interruption.

8.3 Blocked Vent Switch

Describes the blocked vent shutoff system and its function.

8.5 Pilot and Ignition Systems

Information on intermittent spark pilot systems and safety features.

9.0 Commissioning and Startup

9.1 Check the installation prior to startup

Checklist for pre-startup inspections like suspension, electrical, clearances, and venting.

9.2 Startup

Steps for starting up the furnace, including operating sequence.

9.3 Check installation after startup

Procedures for checking manifold pressure, burner flame, and limit control.

10.0 Maintenance and Service

10.3 Troubleshooting