EasyManuals Logo

Rheem 325 II Series User Manual

Rheem 325 II Series
76 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #24 background imageLoading...
Page #24 background image
24
This document is stored and maintained electronically by Service. All printed copies are deemed uncontrolled.
Element Mode Fault
FIRMWARE: V5.8
M
At least 45 minutes
since the compressor
last ran?
Evaporator sensor
< 1ºC for more than
15 minutes?
Circulator on
Circ. Speed: Maximum
Green LED 4 flashes
Red LED Off
Circulator has been
on for 30 seconds?
Red LED Off
Element off
Controller off
YES
At least 15 minutes
since the circulator
last ran?
A
YES
Faults 1, 5 or 6
detected?
NO
NO
NO
NO
Reset button pressed
at any stage
B
NOTE
The reset button will clear the stored
Fault Code from the controller memory.
Mechanical
thermostat contacts
open at 70ºC?
Faults 1, 5 or 6
current?
NO YES
NO
YES
Main relay energised
Element off
YES
Circulator off
Green LED Off
Red LED Display
current Fault Code
YES
Element on
Main relay de-energised
NO YES

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Rheem 325 II Series and is the answer not in the manual?

Rheem 325 II Series Specifications

General IconGeneral
BrandRheem
Model325 II Series
CategoryHeat Pump
LanguageEnglish

Related product manuals