13
HEAT PUMP AND TANK ASSEMBLY
STORAGE TANK AND HEAT PUMP MODULE
The heat pump water heater is made of two main components, the storage tank
and the heat pump module. For transport and handling (weight) purposes both
items are shipped separately and designed to be assembled at the installation
site. The water heater must not be operated until both components are
assembled.
The water heater is to be installed at ground or floor level and must stand
vertically upright on a stable base, as acceptable to local authorities, of a
minimum 900 mm wide x 650 mm deep. The heat pump module must be fully
supported by the stable base.
HEAT PUMP MODULE
The heat pump module is shipped in a box containing two hand holes to
facilitate easy handling and lifting. The heat pump module is to be mounted
against the side of the storage tank.
CAUTION: The heat pump module weighs approximately 42 kg. Use the hand
holes provided in the sides of the packaging. Good lifting practice should be
followed.
There are two flexible hoses provided inside the heat pump module. The
flexible hoses are to be withdrawn from the module and fixed to the two water
fittings on the heat pump storage tank, during the assembly procedure.
There are two connection points located on the underside of the control box in
the heat pump module to which the power cable and tank sensor cable from
the heat pump storage tank are connected, during the assembly procedure.
STORAGE TANK
The storage tank is designed to receive the heat pump module. There are two
water fittings located at the side of the storage tank to which flexible hoses from
the heat pump module are connected, during the assembly procedure.
A power cable is housed behind the lower cover and a tank sensor cable is
located adjacent to and above to the lower cover of the storage tank. The
power cable is to be withdrawn from behind the front cover and the tank sensor
cable unfurled and both connected to the control box in the heat pump module
during the assembly procedure.