EasyManua.ls Logo

Rheem R95P - Page 21

Rheem R95P
100 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
21
Field Conversions
(X2)
9b - RIGHT SIDE DRAIN OPTION
ATTACH HOSE A (FACTORY INSTALLED) TO BULKHEAD COUPLING.
INSTALL CLAMP OVER HOSE ON BULKHEAD COUPLING.
OPTION
9b
DRAIN RIGHT SIDE
HOSE A
NOTE:
USE SOAPY WATER TO FACILITATE EASY
HOSE AND TUBE ASSEMBLY
9a - LEFT SIDE DRAIN OPTION
9a -1- REMOVE HOSE A (FACTORY INSTALLED ON CONDENSATE TRAP) & REPLACE
WITH HOSE B REUSING SUPPLIED CLAMP.
9a -2- CUT TUBE C ON MARKED LINES CORRESPONDING TO CABINET WIDTH.
9a- 3- ROTATE RUBBER HOSE ON TUBE C SO THAT SIDE "1" CONNECTS TO PVC &
SIDE "2" TO BULKHEAD COUPLING. INSTALL CLAMP OVER HOSE ON
BULKHEAD COUPLING.
9a- 4- INSTALL TUBE C USING HOSE CLAMP.
ATTACH SIDE "2" TO BULKHEAD
COUPLING
OPTION
DRAIN LEFT SIDE
9a
TUBE C
CUT TO FIT
CABINET WIDTH
9a-3
9a-2
SWAP
ENDS
9a-1
1
2
TUBE C
HOSE B
9a-4
NOTE:
USE SOAPY WATER TO FACILITATE EASY
HOSE AND TUBE ASSEMBLY
8
INSTALL BULKHEAD COUPLING USING (2) SCREWS.
INSTALL IN JACKET WITH THE BARBED FITTING
POINTED INTO THE VESTIBULE.
INSTALL
1/8" DRILL
DISCARD
7/8" PLUG
1/8" DRILL
DISCARD
7/8" PLUG
DETERMINE RIGHT OR LEFT DRAIN OPTION.
LOCATE 7/8" HOLE IN JACKET SIDE AND REMOVE PLUG - DISCARD.
DRILL (2)
1/8" HOLES FOR BULKHEAD COUPLING.
OPTION: RIGHT DRAIN
OPTION: LEFT DRAIN
7
6b
6e
6d
6c
6
HOSE E
HOSE D
6b - INSTALL CONDENSATE TRAP BY MOUNTING BRACKET TO JACKET USING (2) SCREWS
6c - CUT 1/4” VENT TUBE TO FIT (APPROX. 10-1/2"). INSTALL AS SHOWN.
6d - INSTALL HOSE D (REMOVED IN STEP 1) FROM INDUCER COUPLING TO THE FLUE
TAP IN THE CONDENSATE TRAP.
6e - INSTALL HOSE E FROM COLLECTOR BOX TO TOP OF CONDENSATE TRAP.
-2010°
APPROXIMATELY 10-20° TILT
ON INDUCER COUPLING
GROUND
ROTATE INDUCER COUPLING TO ENSURE
DOWNWARD FLOW OF CONDENSATE FROM
FLUE VENTING
6a
NOTE:
USE SOAPY WATER TO FACILITATE EASY
HOSE AND TUBE ASSEMBLY
1/4” TUBE CUT
TO FIT (APPROX
10-1/2”)
ST-A1194-30-X0
NOTE: REMAINING STEPS SHOWN WITH FURNACE IN DOWN FLOW ORIENTATION
SEE CRITICAL HOSE CLAMP LOCATION NOTE
IN THE GENERAL COVERSION INSTRUCTIONS.