AIR FLOW PERFORMANCE
AIRFLOW
Low 732 695 669 639 605 547 512 487
Med. Lo 875 845 820 792 766 726 659 605
Med. Hi* 1073 1049 1004 975 943 900 864 798
High 1279 1239 1213 1174 1121 1069 1033 980
Low 830 793 755 705 654 599 544 496
Med. Lo 940 908 875 821 766 710 653 584
Med. Hi* 1168 1139 1109 1060 1010 942 874 802
High 1421 1385 1349 1291 1232 1147 1062 976
Low 852 827 802 752 701 662 623 580
Med. Lo 986 955 923 883 843 790 737 686
Med. Hi* 1238 1211 1183 1139 1094 1036 978 897
High 1493 1452 1410 1364 1318 1257 1195 1084
Low 1313 1275 1236 1221 1184 1141 1098 1053
Med. Lo 1488 1452 1415 1384 1328 1279 1229 1170
Med. Hi* 1732 1704 1676 1630 1579 1498 1417 1343
High 1983 1929 1874 1810 1742 1663 1583 1477
Low 1329 1313 1296 1260 1224 1171 1117 1049
Med. Lo 1535 1498 1461 1422 1382 1325 1268 1203
Med. Hi* 1796 1748 1700 1656 1612 1536 1460 1370
High 2019 1961 1903 1843 1782 1687 1592 1489
Low 1249 1234 1219 1183 1146 1112 1078 1017
Med. Lo 1440 1429 1417 1381 1344 1313 1281 1221
Med. Hi* 1770 1750 1730 1696 1662 1611 1559 1463
High 2123 2077 2031 1983 1934 1856 1777 1665
TABLE 17
AIR FLOW PERFORMANCE (-)95P SERIES MODELS
Model
Motor HP [W]
Blower Size
IN [MM]
CFM Air Delivery
External Static Pressure, ”W.C. [kPa]
Speed Tap 0.1 [0.02] 0.2 [0.05] 0.3 [0.07] 0.4 [0.10] 0.5 [0.12] 0.6 [0.15] 0.7 [0.17] 0.8 [0.19]
(-)95PA
0401
317MSA
1/4 [187]
11 x 7
[279 x 178]
(-)95PA
0601
317MSA
(-)95PA
0701
317MSA
(-)95PA
0851
521MSA
(-)95PA
1001
521MSA
(-)95PA
1151
524MSA
1/2 [373]
11 x 8
[279 x 203]
1/2 [373]
11 x 8
[279 x 203]
3/4 [559]
11 x 10
[279 x 254]
3/4 [559]
11 x 10
[279 x 254]
3/4 [559]
11 x 11
[279 x 279]
*Factory Setting For Heat
All shaded cells are valid heating settings. Do not use speed taps and/or static pressures which do not fall into the shaded cells on this table.
BLOWER SPEED SELECTIONS
The furnace controls have four active quick connect termi-
nals for connecting the motor speed leads. These are:
1. FAN — motor runs on this speed when the thermostat
is in the “FAN ON” position.
2. COOL — connect desired cooling speed.
3. HEAT — connect desired heating speed.
4. H/C (for heat/cool) — connect desired speed when
heating and cooling speed are the same.
In addition to the active motor terminals, there are two
motor parking terminals (labeled M1 and M2) available for
placing any unused motor taps. All unused motor taps
should be connected to either M1 or M2. These terminals
(M1 and M2) will not be energized under any condition.
IMPORTANT: Do not connect any motor speeds to “HEAT”
and/or “COOL” if you use the “HEAT/COOL” terminal.
5. If heating and continuous fan speed are the same,
“piggyback” jumper across “FAN” and “HEAT” termi-
nals.
If cooling speed and fan speed are desired to be the same,
this may be accomplished by not connecting “Y” to the in-
tegrated furnace control.
IMPORTANT: If desired for cool, fan and heat to all be
the same speed, then “piggyback” jumper “H/C” to
“FAN” and do not connect “Y” to the integrated fur-
nace control. Do not connect anything to “Heat” or
“Cool.
See selection titled “Field Selections – Dipswitches” for
setting the heating and cooling blower off delay times.
Air Flow