98
TABLE 25: CONFIGURATION MENU
Non-Displayed Press
or
Program- Program- Press (Factory to select from
mable mable Button Default) listed options Comments
11 MS 2 HP 1, HP 2, SS 1Selects Multi-Stage (MS 2, No Heat Pump), Heat Pump 1
(HP 1, 1 compressor), Heat Pump 2 (HP 2, 2 compressor
or 2 speed compressor), or Single Stage.
22
(GAS) ELE GAS setting: furnace controls blower.
ELE setting: thermostat controls b l o w er.
33
Days, (7) P5-1-1 or 0 Programs per week. (0 = non-programmable)
4 NA
PS (4) 2 Program periods per d ay.
Morning, Day, Day, Night 4 = Morning, Day, Evening, Night
thgiN ,yaD = 2thgiN,gninevE
54
Cool-Off- Cool-Off-Heat, System switch configuration in non heat pump mode.
Heat-Auto Off-Heat, Cool-Off
Cool-Off-Heat- Cool-Off-Heat-Emer, S ystem switch configuration, heat pump mode.
Emer-Auto Off-Heat-Emer, Cool-Off
6 NA
E (On) OFF Selects Energy Management Recovery, E (with programming option on)
75
C r, Heat (FA) SL Selects Adjustable Anticipation, cycle rate, Heat
86
C r, Cool (FA) SL Selects Adjustable Anticipation, cycle rate, Cool
97
Cr/AU, Emer (FA) SL Selects Adjustable Anticipation, cycle rate auxiliar y, ( This item is
only to appear if HP 1 or HP 2 is selected above).
10 8
CL (OFF) On Selects Compressor Lockout.
11 9
dL (On) OFF Selects Continuous Display backlight & intensity.
12 10
dL (LO) HI Selects Backlight Intensity.
13 11
0 4, LO to 4, HI Selects Adjustable Ambient Temperature Display [range -4 (LO) to
+4 (HI)].
14 12
FCSelects F/ C Displa y (temperature units in Fahrenheit or Celsius).
15 13
b (On) OFF Selects audible Beeper On/Off.
16 14
dS (On) OFF Selects Daylight Saving Time calculation.
17 15
AS, Heat (OFF) On Selects Automatic Schedule for comfort temperature Programming,
heat mode.
18 16
AS, Cool (OFF) On Selects Automatic Schedule for comfort temperature Programming,
cool mode.
19 17
CS, (OFF) 1-2-3-4-5-6 Selects Cool Saving Feature & amount.
Cool Savings
20 18
HL, Heat (99) 62-98 TEMPERATURE LIMIT, HEAT (max. heat set point).
21 19
LL, Cool (45) 46-82 TEMPERATURE LIMIT, COOL (min. cool set point).
22 20
O F F, L (total), P (partial), Selects Keypad Lockout.
Keypad LockoutTemperature Limit
(limited temperature range)
000 001-999 Selects Keypad Lockout Combination (active only if keypad Lockout
is selected).
23 21
FS, Heat (On) OFFFast second stage of heat (not available if SS1 is selected above).
24 22
FS, Cool (On) OFFFast second stage of cool (not available if SS1 or HP1 is selected
above).
25 23
Remote (OFF) On Remote temperature sensor, enable/disable.
In, Remote Outdoor RemoteRemote temperature sensor (Indoor/Outdoor).
LS (On) OFF Local temp. Sensor enable/disable (only when Indoor Remote is
selected On).
26 24
dF (5) 5-50 Selects Dual Fuel Feature & setpoint (in Fahrenheit) (applicable only
when HP1 or HP2 is selected).
Cd (15) 0-99 Selects Compressor delay in seconds (only when dF is selected >5).
27 25
AO (80) 35 to 80 Selects Auxiliary Off setpoint (applicable only when HP1 or HP2
is selected).
28 26
Change Filter On Selects Change filter feature
(OFF)
200 Hours 25-1975 (in increments Change filter, duration hours.
of 25 hours)
INSTALLER/CONFIGURATION MENU
To enter the menu: Press the Menu touch key. Press and hold for 5 seconds the Installer Config touc h ke y. This displays
menu item #1 in Table 25 below. Press
to advance to the next menu item or to return to a previous menu item. Press
or to change a menu item.
Menu
Reference
Number
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
21
22
23
24
25
26
27
28