K500
With functioning in hold-to-run man mode when the safety devices are failing.
Operator Power Supply Max gate weight Max Thrust Max torque Code
K500 230V 50/60Hz 500 kg / 1103 lbs 400 N 9,5 Nm AA33694

Questions and Answers

  • A
    Angela CarterAug 10, 2025
    What to do if the RIB AA33694 doesn't open or close with K and RADIO buttons?
    • J
      jessicagrantAug 10, 2025
      If your RIB Garage Door Opener doesn't open or close when you use the K and RADIO buttons, the issue might be a faulty safety edge contact or faulty photocells contact with DIP 4 OFF. You should fix or replace the faulty contact to resolve this.
  • A
    amanda43Aug 15, 2025
    Why does my RIB AA33694 Garage Door Opener open but not close after the set time?
    • D
      Dean MillerAug 15, 2025
      If your RIB Garage Door Opener opens but doesn't close after the set time, ensure that DIP 3 is set to ON. Also, make sure the K BUTTON is always inserted in automatic functioning mode (DIP 6 OFF). If the issue persists, replace the button or switch of the selector switch. Check the connections between the electronic board and edge feeder. If you're not using a feeder for edges, DIP 10 must be at the OFF position.
  • K
    Kayla RoblesAug 21, 2025
    How to fix a RIB AA33694 Garage Door Opener motor that opens and closes slowly with no strength?
    • T
      Tiffany CervantesAug 21, 2025
      If your RIB Garage Door Opener motor opens and closes but lacks strength and moves slowly, check the TORQUE and LOW-SPEED adjustment trimmers.
  • R
    Richard WebsterAug 26, 2025
    Why is the slowing phase not working on my RIB AA33694?
    • B
      Barbara NelsonAug 26, 2025
      If the slowing phase isn't working on your RIB Garage Door Opener, make sure DIP 8 is in the OFF position to enable slowing. You may need to relearn the times through procedure from DIP 2. Also, check the LOW-SPEED adjustment trimmer.
  • R
    Robert TrevinoAug 30, 2025
    What to do if the RIB AA33694 gate does not move when activating the K button?
    • L
      Luis JimenezAug 30, 2025
      If your RIB Garage Door Opener gate doesn't move when you press the K button, the impulse K might be always inserted. Check and replace any faulty buttons or micro-switches of the selector switch.
  • L
    Lauren EdwardsSep 4, 2025
    How to troubleshoot all LEDs being off on a RIB AA33694 Garage Door Opener?
    • C
      Colleen StewartSep 4, 2025
      If all the LEDs are off after connecting and supplying voltage to your RIB Garage Door Opener, check the integrity of fuses F1 and F2. If a fuse is interrupted, replace it with one of the correct value: F2 = 5A, F1 = 100mA.

RIB AA33694 Specifications

General IconGeneral
Input Voltage120 VAC
Relay OutputSPDT
Voltage120 VAC
Current Rating10A
Contact TypeSPDT
Mounting TypeDIN Rail
Contact Ratings10A @ 120V AC
Operating Temperature-30 to 140° F