1st Menu 2nd Menu 3rd Menu 4th Menu
Service Mode Engine Maintenance 2nd Transfer
Front
Back
[-15 to +15/ 1 step]
This adjusts the transfer roller current, based on the default value.
The range of adjustment is from -15 [μA] to +15 [μA], in units of 1.
The printer will warm up automatically after this setting is changed.
1st Menu 2nd Menu 3rd Menu 4th Menu
Service Mode Engine Maintenance 2nd Transfer Fuser Temp
[0 to -30/ 1 step]
This adjusts the offset temperature of the fusing unit, based on the default value. The range of adjustment
is from -30 [°C] to 0[°C], the unit is 2.
The printer will warm up automatically after this setting is changed. *2
1st Menu 2nd Menu 3rd Menu 4th Menu
Service Mode Engine Maintenance Registration
Tray 1
Tray 2
By-pass
Duplex
5th Menu
• Vertical
• Horizontal
[-15 to +15/ 0.33 mm/ 1 step]
This adjusts the vertical and horizontal registration for each tray.
If the machine settings are reset to the factory defaults, this value does not change.
Clear Log (2nd Menu)
This resets all log data.
4. Appendix: SP Mode Tables