Main SP Tables-1
System Maintenance Section 2-29 D146/D147/D148/D149/D150
008
Plain2:BW:Press *ENG
[0 to 200 / D146:118, D147:118,
D148:118, D149:120, D150:120 /
1deg/step]
Do not change. paper through target temperature: Standard paper 2: BW:
pressure
009
Thin:FC:Center *ENG
[100 to 180 / D146:114, D147:114,
D148:116, D149:132, D150:132 /
1deg/step]
Paper through target temperature: thin paper: FC: center
Fusing malfunction might improve by setting value larger.
Paper curl might improve by setting value smaller.
Adjusting range is +/- 5 deg. celsius.
010
Thin:FC:Press *ENG
[0 to 200 / D146:114, D147:114,
D148:116, D149:132, D150:132 /
1deg/step]
Do not change. paper through target temperature: thin paper: FC: pressure
011
Thin:BW:Center *ENG
[100 to 180 / D146:114, D147:114,
D148:116, D149:132, D150:132 /
1deg/step]
Paper through target temperature: thin paper: BW: center
Fusing malfunction might improve by setting value larger.
Paper curl might improve by setting value smaller.
Adjusting range is +/- 5 deg. celsius.
012
Thin:BW:Press *ENG [0 to 200 / 118 / 1deg/step]
Do not change. paper through target temperature: thin paper: BW: pressure
013
M-thick:FC:Center *ENG
[100 to 180 / D146:135, D147:135,
D148:141, D149:157, D150:157 /
1deg/step]
Paper through target temperature: middle thick paper: FC: center
Fusing malfunction might improve by setting value larger.
Paper curl might improve by setting value smaller.
Adjusting range is +/- 5 deg. celsius.