Main SP Tables-1
D146/D147/D148/D149/D150 2-30 System Maintenance Section
014
M-thick:FC:Press *ENG
[0 to 200 / D146:118, D147:118,
D148:118, D149:140, D150:140 /
1deg/step]
Do not change. paper through target temperature: middle thick paper: FC:
pressure
015
M-thick:BW:Center *ENG
[100 to 180 / D146:135, D147:135,
D148:141, D149:152, D150:152 /
1deg/step]
Paper through target temperature: middle thick paper: BW: center
Fusing malfunction might improve by setting value larger.
Paper curl might improve by setting value smaller.
Adjusting range is +/- 5 deg. celsius.
016
M-thick:BW:Press *ENG
[0 to 200 / D146:118, D147:118,
D148:118, D149:140, D150:140 /
1deg/step]
Do not change. paper through target temperature: middle thick paper: BW:
pressure
017
Thick1:FC:Center *ENG
[100 to 180 / D146:125, D147:125,
D148:140, D149:140, D150:140 /
1deg/step]
Paper through target temperature: thick paper 1: FC: center
Fusing malfunction might improve by setting value larger.
Paper curl might improve by setting value smaller.
Adjusting range is +/- 5 deg. celsius.
018
Thick1:FC:Press *ENG [0 to 200 / 118 / 1deg/step]
Do not change. paper through target temperature: thick paper 1: FC: pressure
019
Thick1:BW:Center *ENG
[100 to 180 / D146:125, D147:125,
D148:140, D149:140, D150:140 /
1deg/step]
Paper through target temperature: thick paper 1: BW: center
Fusing malfunction might improve by setting value larger.
Paper curl might improve by setting value smaller.
Adjusting range is +/- 5 deg. celsius.