Main SP Tables-1
D146/D147/D148/D149/D150 2-36 System Maintenance Section
Paper through target temperature: special paper 3: FC: center
Fusing malfunction might improve by setting value larger.
Paper curl might improve by setting value smaller.
Adjusting range is +/- 5 deg. celsius.
060
Special3:FC:Press:Middle
Speed
*ENG [0 to 200 / 118 / 1deg/step]
Do not change. paper through target temperature: special paper 3: FC:
pressure
061
Special3:BW:Center:Middle
Speed
*ENG
[100 to 180 / D146: 132, D147: 132,
D148: 151, D149: 151, D150: 151 /
1deg/step]
Paper through target temperature: special paper 3: BW: center
Fusing malfunction might improve by setting value larger.
Paper curl might improve by setting value smaller.
Adjusting range is +/- 5 deg. celsius.
062
Special3:BW:Press:Middle
Speed
*ENG [0 to 200 / 118 / 1deg/step]
Do not change. paper through target temperature: special paper 3: BW:
pressure
101
Plain1:FC:Center:Low Speed *ENG [100 to 180 / 115 / 1deg/step]
Paper through target temperature: Standard 1: FC: center: low speed
Fusing malfunction might improve by setting value larger.
Paper curl might improve by setting value smaller.
Adjusting range is +/- 5 deg. celsius.
102
Plain1:FC:Press:Low Speed *ENG [0 to 200 / 118 / 1deg/step]
Do not change. paper through target temperature: Standard 1: FC: pressure:
low speed
103
Plain1:BW:Center:Low Speed *ENG [100 to 180 / 115 / 1deg/step]
Paper through target temperature: Standard 1: BW: center: low speed
Fusing malfunction might improve by setting value larger.
Paper curl might improve by setting value smaller.
Adjusting range is +/- 5 deg. celsius.